Sign In | Join Free | My himfr.com
himfr.com

Shenzhen Hunt Electronics Co., Ltd

Shenzhen Hunt Electronics Co., Ltd Shenzhen Hunt Electronics Co.,Ltd. is primarily engaged in developing and manufacturing semiconductor products.

Active Member

9 Years

Home > Mitsubishi PLC Extension Module >

Mitsubishi FX Series PLC Extention Modules FX3U-4DA-ADP Description: Analogue output module, 12 bit, 4 analogue outputs

Shenzhen Hunt Electronics Co., Ltd
Contact Now
    Buy cheap Mitsubishi FX Series PLC Extention Modules FX3U-4DA-ADP Description: Analogue output module, 12 bit, 4 analogue outputs from wholesalers
     
    Buy cheap Mitsubishi FX Series PLC Extention Modules FX3U-4DA-ADP Description: Analogue output module, 12 bit, 4 analogue outputs from wholesalers
    • Buy cheap Mitsubishi FX Series PLC Extention Modules FX3U-4DA-ADP Description: Analogue output module, 12 bit, 4 analogue outputs from wholesalers

    Mitsubishi FX Series PLC Extention Modules FX3U-4DA-ADP Description: Analogue output module, 12 bit, 4 analogue outputs

    Ask Lasest Price
    Brand Name : Mitsubishi
    Model Number : FX3U-4DA-ADP
    Certification : CE
    Price : USD170~200/PCS
    Payment Terms : T/T
    Supply Ability : 1000PCS/week
    Delivery Time : in stock
    • Product Details
    • Company Profile

    Mitsubishi FX Series PLC Extention Modules FX3U-4DA-ADP Description: Analogue output module, 12 bit, 4 analogue outputs

    Product Specifications

    • Part Number: FX3U-4DA-ADP
    • Manufacturer: Mitsubishi
    • Our part number: FX3U4DAADP

    Information about this range

    Analogue output module, 12 bit, 4 analogue outputs for current or voltage

    4AD module with 4 channels suitable for 0-10V and 4-20mA analogue inputs
    4DA module with 4 channels suitable for 0-10V and 4-20mA analogue outputs
    4AD-PT module with 4 channels suitable for PT100 temperature probes/ analogue inputs
    4AD-TC module with 4 channels suitable for thermocouple temperature probes/ analogue inputs

    Manufacturer's Part No.Analogue RangeCompensation Temperature Range
    FX3U-4AD-ADP0 to 10Vdc, 4 to 20mA2.5mV/10μA
    FX3U-4DA-ADP0 to 10Vdc, 4 to 20mA2.5mV/10μA
    FX3U-4AD-PT-ADP0.1°C-50 to 250°C
    FX3U-4AD-TC-ADP0.3°C (J type)/ 0.4°C (K type)-100°C to 600°C (J type) -100°C to 1000°C (K type)

    Note

    These modules fit on the left-hand side of FX3U base units and require one of the following modules to connect to the PLC: FX3U-232-BD (539-0869), FX3U-422-BD (539-0875), FX3U-485-BD (539-0881), FX3U-USB-BD (539-0897), FX3U-CNV-BD (539-0904). Supply voltage is taken from PLC base unit.

    Mitsubishi FX3U

    FX3U CPU's are compatible with existing FX2N expansion modules as well as the new FX3U ADP expansion modules and may be used as a replacement for FX2N PLC's.


    Specifications
    Not what you’re looking for? Select the attributes you require, then click the button below
    Manufacturer SeriesMELSEC FX
    Number of Outputs4
    Output TypeAnalogue, Relay, Transistor
    For Use WithMELSEC FX Series
    Number of I/O4
    Voltage Category5 → 24 V dc
    Length90mm
    Width17.6mm
    Depth89.5mm
    Dimensions90 x 17.6 x 89.5 mm


    For more specifications

    Name of productAnalog output
    Form nameFX3U-4DA-ADP
    Standard fitCE (EMC), UL/cUL, KC, ABS, DNV, LR, GL, BV, RINA, NK, KR
    Performance specificationsAnalog outputAnalog output rangeVoltage output DC0V-10 V (external load 5 k Ω ~ 1 M Ω)
    Current output DC4mA ~ 20 mA (external load 500 Ω below)
    Number of output channels4-channel
    Output characteristicsIndividually for each channel, you can set output mode (voltage / current output).
    Digital input12-bit binary
    ResolutionVoltage output 2.5 mV (10 V × 1 / 4000)
    Current output 4 μA (16mA×1 / 4000)
    Overall accuracyVoltage output
    Ambient temperature 25 ° c ± 5 ° c: for full scale 10 V ± 0.5% (± 50 mV)
    Ambient temperature 0 ° c ~ 55 ° c: for full scale 10 V ± 1.0% (± 100 mV)
    External load resistance (Rs) 5 k under the Ω of the following calculations: increases. (Increases 1% per 100 mV)
    (47 × 100) ÷ (Rs+47)?0.9(%)
    Current output
    Ambient temperature 25 ° c ± 5 ° c: for full scale 16 mA ± 0.5% (± 80 μA)
    Ambient temperature 0 ° c ~ 55 ° c: for full scale 16 mA ± 1.0% (± 160 μA)
    D/a conversion timeFX3U/FX3UC sequencer 200 µ s (data updated every operation cycle)
    FX3G/FX3GC sequencer 250 μ s (data updated every operation cycle)
    Insulation scheme-Analog output channels and between the sequencer is isolated by Photocoupler
    -Analog output, and power supply between the isolated DC/DC converter by
    ? Each channel between the non-insulated.
    The occupancy number0 points (unrelated to maximum input and output number of sequencer )
    Apply sequencerFX3G, FX3U, FX3GC, FX3UC (the FX3UC-32MT-LT Ver.1.20 or later)
    Connection to FX3G is a FX3G-CNV-ADP is required.
    FX3U and FX3UC-32MT-LT (-2) connecting the function expansion board is required.
    Mass0.1 kg
    General specificationsAmbient temperature0-55 ° c, and operating: -25 ~ 75 ° c, and save time
    Relative humidity... Operating 5 ~ 95% RH (non-condensing):
    Vibration resistanceDIN rail mounting:< Frequency: 10-57 Hz > piece amplitude: 0.035 mm X, Y, Z directions 10 times (total 80 minutes each)
    DIN rail mounting:< Frequency: 57-150 Hz > acceleration :4.9m/s2 X, Y, Z directions 10 times (total 80 minutes each)
    Direct mounting:< Frequency: 10-57 Hz > piece amplitude :0.075mm X, Y, Z directions 10 times (total 80 minutes each)
    Direct mounting:< Frequency: 57-150 Hz > acceleration :9.8m/s2 X, Y, Z directions 10 times (total 80 minutes each)
    Impact resistance147 m / s 2 the interaction time is X, Y, Z directions three times in 11 ms half-sine pulse
    Noise immunityNoise voltage rise 1,000 VP-p, noise width 1 μs, a 1 ns, 30-100 Hz noise Simulator
    Withstand voltageBulk all Terminal and ground terminal while: AC 500v for 1 minute
    Insulation resistanceBulk all Terminal and ground terminal between :DC500V Megger at Ω over 5 M.
    GroundingD seeds ground (ground resistance: below 100 Ω) [common grounding and electrical system is unavailable]
    Grounding is only on the ground or common ground and see.
    Operating atmosphereNot corrosive, flammable gas, conductive dust (dust) is not severe
    Use advancedless than 2000 m
    Under the pressure exceeding atmospheric pressure environment cannot be used. You may fail.
    Power supply specificationsPower supplyDC5V15mA (internal power supply from the sequencer)
    DC24V+20%-15% 150ma (external power supply)